Home / Maintenance
Care & inspection

Keep your cylinder in service

A pressure vessel is only as safe as its last inspection. Rinse it, store it right, and keep it within test — and it stays fillable, legal and safe for years.

20–30 bar residual in storage
Annual visual inspection
5 yr hydrostatic retest
Silicone grease only
Three habits

After every dive

Most cylinder problems start on the surface, not underwater. These three habits prevent nearly all of them.

RINSE

Fresh water, every time

Rinse the cylinder and valve after salt water, paying attention to the valve area and base. Don’t immerse an open valve with the regulator removed — water enters the seat.

STORE

Upright, with pressure

Keep 20–30 bar residual so moisture and contaminants can’t get in. Store upright. Never leave a fully pressurised cylinder in a hot car or direct sun.

CAP

Fit the dust cap

Whenever the regulator is off, fit the valve dust cap to keep the bore and O-ring clean and dry.

What you need

The care kit

Don’t overlook

The boot and the valve

Two spots do most of the quiet damage. Salt water trapped under a rubber boot accelerates external corrosion — remove the boot periodically to inspect and dry the base. And the valve’s bore O-ring is your primary gas seal — check it often.

  • Inspect the DIN bore O-ring before each use; replace if cracked, flat or deformed
  • Lubricate O-rings with silicone grease only — never petroleum-based
  • Hand-tight plus a half turn on the DIN insert; over-torque damages threads
  • Service the valve annually — burst disc and seat are a technician’s job
Pre-dive valve check30 sec
Bore O-ringintact?
Dust capoff & clean?
Open testfull + ¼ back
Smell / tastegas clean?
Pressureas expected?
A few seconds before kitting up saves a thumbed dive.
Inspection

Testing & intervals

A cylinder with an expired test date can’t be filled at a commercial station. Know your dates — they’re stamped on the shoulder.

CheckInterval (typical, EU)Who
Visual inspectionAnnual (per local rule)Qualified inspector
Hydrostatic test (EN 1964)Every 5 yearsTesting body
Valve serviceAnnual / as recommendedTrained technician
O-ring checkBefore each useYou

Intervals vary by country and inspection body — confirm what applies in your region with your dive shop or fill station.

Never Don’t paint over or obscure the shoulder stamps (working pressure, capacity, test dates). Don’t store cylinders fully pressurised in confined, hot spaces. Don’t fit a burst disc or valve rated to a different working pressure than the cylinder. Don’t fill a cylinder with an expired test date.
Enriched air

Nitrox needs more than a green band

For EAN above 21%, a cylinder must be oxygen-clean inside — free of hydrocarbon contamination — and fitted with an oxygen-rated, oxygen-clean valve. It carries the nitrox markings: the green-and-yellow band and the EAN content label. Most fill stations want a valid oxygen-cleaning certificate before they’ll fill nitrox.

Time for a new cylinder or valve?